Every POS terminal shipped into the European Union or the United States arrives with a folder of compliance documents, and every importer is told those documents make the product legal to sell. Some of what is in that folder has real legal weight; some of it is a test report with no defined validity; some of it covers the terminal but not the adapter in the same box. Knowing which is which decides whether a shipment clears customs without argument, whether a marketplace listing survives an audit, and whether the importer carries a liability that the factory never mentioned.
This note sets out what CE, RoHS and FCC documentation actually consists of for an all-in-one POS terminal, what each document proves, and the gaps that most often appear between what a supplier sends and what a buyer needs. It is written for distributors and importers placing OEM or white-label orders, not as legal advice; national market-surveillance practice still varies by member state.
The confusion starts because all three names are used loosely to mean "certificate". In practice they describe three different legal mechanisms:
So when a supplier says "we have CE certificate", the correct follow-up question is: which document, issued by whom, for which model, covering which standards? The answer is usually an EU Declaration of Conformity plus one or more EMC and safety test reports — and it is those underlying documents that carry the weight.
For a POS terminal the applicable directives are normally:
The document the importer should receive is the EU Declaration of Conformity. It is issued by the manufacturer or the importer placing the product on the market, and it must name the product and model, list the directives and harmonised standards applied, identify the responsible legal person in the EU, and be signed. Alongside it the manufacturer must hold technical documentation — design records, test reports, risk assessment, bill of materials evidence — and keep it available to authorities for at least ten years after the last unit is placed on the market.
Two practical points follow. First, a DoC that names one model does not automatically cover a variant with a different panel, a different motherboard or a different adapter; the technical file has to match the configuration actually shipped. Second, the DoC is a legal claim by whoever signs it. An importer who puts their own brand on the product can become the responsible economic operator, which means the obligation to hold the technical file transfers with the branding.
The Low Voltage Directive covers equipment rated between 50 and 1,000 volts AC, or between 75 and 1,500 volts DC. A POS terminal that runs from a 24V DC input is below that threshold, so the terminal itself is generally outside LVD scope. The external AC/DC adapter in the same carton is not: its mains input sits squarely inside the range, and it needs its own safety evidence, normally to EN 62368-1 together with the relevant national deviations.
This split is the single most common documentation gap in POS shipments. The terminal's file is complete, the adapter's is missing or borrowed from a different model, and the combined product has no coherent safety story. An importer checking a folder should confirm that the adapter model named in the DoC is the adapter actually in the box, and that its safety report exists as a separate document.
RoHS restricts ten substances: lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, polybrominated diphenyl ethers, and the four phthalates DEHP, BBP, DBP and DIBP. Limits are 0.1 percent by weight in homogeneous material, except cadmium at 0.01 percent.
What a typical RoHS report contains is a set of results for specific samples, broken down by homogeneous material — a solder joint, a cable jacket, a housing alloy, a coating. Three limitations matter commercially:
The exemptions list also matters. Certain applications still rely on time-limited exemptions, and a supplier claiming RoHS compliance should be able to say whether any exemption is being used for the product and, if so, which one and until when.
In the United States, an all-in-one POS terminal is an unintentional radiator under FCC Part 15 Subpart B. The applicable route is the Supplier's Declaration of Conformity: the responsible party — normally the US importer or the manufacturer's US agent — tests to the relevant standard, keeps the test report and a compliance statement, and does not obtain an FCC ID. There is no "FCC certificate" for the terminal, and an offer to sell one is usually either a mislabelled SDoC package or a third-party "certificate" with no regulatory standing.
The radio module is a different case. A Wi-Fi or Bluetooth module is an intentional radiator under Subpart C and must hold its own certification and FCC ID. If the module is pre-certified, the terminal can generally rely on the module grant provided the module is installed per its grant conditions and the host labelling requirements are met. If the supplier has designed a radio circuit onto the main board instead of using a pre-certified module, the terminal itself needs a certification and an FCC ID, which changes both cost and lead time.
Importers should therefore check two separate items: the terminal's SDoC, and the radio module's grant with its FCC ID and the grantee's name. A folder containing only one of the two is incomplete for a terminal with wireless capability.
Part 15 Subpart B splits equipment into two classes. Class B applies to equipment used in residential environments and carries tighter emission limits. Class A applies to commercial, industrial or business environments and is less strict, but the equipment must carry a notice that it is a Class A product and may cause interference in residential areas.
A POS terminal used on a retail counter is normally argued as Class A, which is cheaper and simpler to certify. That classification is a statement about the intended environment, and it has consequences: a distributor who resells the same terminal into a small home office, a pop-up shop inside a residential building, or a mixed-use site is placing Class A equipment in an environment the declaration did not assume. In practice most such deployments cause no problem, but in an interference complaint the paperwork is what gets examined. If a model will be sold into both environments, the cleaner route is a Class B declaration from the start.
Five things routinely assumed to be covered are not:
For standard and OEM terminals we provide, per model and per shipment configuration:
Where a buyer needs a specific national requirement — a WEEE registration reference, a Proposition 65 label, a Class B declaration instead of Class A — that is settled at quotation stage, because it changes both the test plan and the label artwork.
CE, RoHS and FCC are not three certificates to be collected; they are three different legal mechanisms with different evidence. The DoC is the document that matters for CE, the adapter needs its own safety file, RoHS is a declaration chain backed by testing rather than a single report, and FCC splits into a terminal declaration and a module certification. Check model consistency, laboratory accreditation, standard versions and scope — and remember that none of it covers reliability, waste registration, the EU responsible person, or the UK and US state rules that sit outside the three regimes.
Terminals in our standard range ship with these files per configuration: the 15-inch Intel-based all-in-one terminal, the 15-inch aluminum-housing till system, and the 15.6-inch 1920×1080 aluminum terminal. For the EMC reasoning behind an aluminum enclosure, see why aluminum housings deliver better EMC for NFC and contactless readers, and for the European waste rules that sit alongside CE, see how EU WEEE rules are shortening POS replacement cycles.
TaixunPOS supplies fanless aluminum POS terminals to European and North American distributors with model-specific compliance packs, and confirms the certification route for each destination market before the order is placed.